      YG611-III/-IV/-V artificial weathering test machine (air-cooled)

      Scope of application 

      Suitable for textiles, paints, dyes, coatings, rubber, plastics, wood floors, paper and other materials for light fastness, weather fastness, light and sweat compound color fastness test and light aging test, with rain, revolution, Weather resistance functions such as rotation and spraying.

      Related standards

      GB/T 8427 ISO105-B02 GB/T8430 ISO105-B04 GB/T14576 AATCC TM16-2003 GB/T15102-2006 GB/T15104-2006 etc.

      technical parameter

      model

       YG611-IIItype

       YG611-IVtype

       YG611-Vtype

      Functionmode

      It has light, rain, light and dark alternation, revolution, and autobiography. The light and dark alternation function strictly complies with the American standard test requirements. The xenon lamp is automatically lit and extinguished at the specified time, and it is automatically adjusted according to temperature and humidity.

       Temperature control range of test chamber

      2570;Resolution:0.1

      2570;Resolution:0.1

      2570;Resolution:0.1

      Test chamber humidity control range

       

       Light cycle: 1070%RH; Resolution: 0.1% Dark cycle: 3095%RH; Resolution: 0.1%

      Standard blackboard thermometer

      4085Accuracy: ±1

      4085Accuracy: ±1

      40100Accuracy: ±1

      Blackboard thermometer(optional)

      4080Accuracy:±2

       4080Accuracy:±2

       4095Accuracy:±2

      Test time control range

       10000h

      Irradiance control range

      0.802.01W/m2@420nm; (340nm, 420nm, 300-400nm and 300-800nm bands are available)

      Accuracy: ±0.02W/m2@420nm; digital setting, closed loop automatic compensation

      Xenon arc lamp rated power

      2.5KW

       3.0KW

       3.5KW

      Rotation speed of sample holder

      Revolution 5r/min; rotation: 180°/revolution (customized)

      The size and number of sample holders that can be installed

      GB:12 pieces of 135*45mm AATCC: 6 pieces 135*75mm

      (Optional) Two-sided clamp sample

      GB: 16 slices 135*45mm

      AATCC:8piecesof 35*75mm

      (Optional) Two-sided clamp sample

      GB: 16 slices 135*45mm

      AATCC: 8 pieces 135*75mm

      (Optional) Two-sided clamp sample

       Each sample holder is timed separately

      10000h

      Photoperiod

      10000h